INSTALLER'S GUIDE
2.17 Propane gas appliances must not be installed in a room that is built entirely below
ground level (See BS 5871 Part 2).
2.18 If the appliance is to be fitted against a wall with combustible cladding, the
cladding must be removed from the area covered by the outer surround. The cladding
must also not touch the surround. (See figure 4). We suggest that the actual surround is
used as a template to mark the area for combustible cladding removal and that this area is
increased by at least 2mm all round. For access to the Fireslide control and to maintain a
2mm gap around the outer case a maximum cladding depth of 6mm is recommended
(See figure 4).
Figure 4. Removal of combustible cladding
Page 10