16.5

To Replace the Control Slide Unit

Remove the front surround - See section 16.3.
1.
Detach the slide unit by removing two screws
2.
securing the plastic slide mechanism to the rear of
the front surround – See figure 57.
Replace in the reverse order.
3.
16.6

To Replace the Control Slide Button

Remove the front surround – See section 16.4.
1.
Detach the slide button by removing two screws –
2.
See figure 57.
Replace in the reverse order.
3.
16.7

To Remove the Burner Unit

Remove the bottom front and
1.
fire front castings and the front
surround - See section 16.3.
Remove the loose coals, the
2.
front coal and the base coal.
Support the inlet isolating
3.
elbow to avoid straining the
pipework and disconnect the
appliance from the elbow.
Detach the burner unit from
4.
the convection box by removing
two screws –See figure 58.
Replace in the reverse order.
5.
16.8
To Remove the Electronic
Ignition Generator
Remove the bottom front and fire
1.
front castings and the front surround -
See section 16.3.
Remove the battery.
2.
Remove the burner unit – see
3.
section 16.6.
If lying the burner on its back,
4.
unscrew and remove the two ceramic
support brackets from the top of the
INSTALLER'S GUIDE
Figure 58. Burner Attachment Points
Page 41
Figure 57. Control slide &
button fixings
Figure 59. Ceramic support bracket