6 G A S S U P P L Y C O N N E C T I O N
A nut and olive are provided for an 8mm pipe inlet connection to the elbow at the bottom
front of the appliance. The elbow can be rotated to allow a connection from any
direction. The elbow includes a valve for isolating the gas supply.
The supply pipe must be rigid material. Flexible pipe must not be used.
6.1
Concealed Supply Pipe Connection
If a concealed connection from inside the fireplace is required then, before the
appliance is fitted into the fireplace it will be necessary to extend the supply line so
that it will project through the chosen removable circular panel at the back of the
convection box and run to the elbow at the front. The pipe run from the supply line up to
the rear opening in the convection box must be kept away from the area which will be
taken by the convection box when it is installed (See figure 7).
Note that the centre of the appliance inlet elbow is 25mm above the fireplace floor. The
inlet elbow should be removed from the appliance and fitted to the supply pipe at this
stage.