Download Print this page
Valor LIMOUSIN BR627 Owner's Manual

Valor LIMOUSIN BR627 Owner's Manual

Inset live fuel effect
Hide thumbs Also See for LIMOUSIN BR627:

Advertisement

INSET LIVE FUEL EFFECT
AS SUPPLIED, THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20)
WHEN CONVERTED USING VALOR CONVERSION KIT NO.591159 THIS
APPLIANCE IS FOR USE WITH PROPANE GAS (G31)
THIS APPLIANCE IS FOR USE IN THE UNITED KINGDOM (GB) AND THE
REPUBLIC OF IRELAND (IE) ONLY.
This guide is intended to help you care for your Valor gas fire. Please read
thoroughly before using and keep for future reference
We trust that this guide gives sufficient details to enable the your appliance to be
operated and maintained satisfactorily. However, if further information is required,
our Valor AdviceLine will be pleased to help.
Please telephone 0345 626341 (Local call rates apply).
This guide to be left with the owner
© Valor Heating
OWNER'S GUIDE
COALFLAME
LIMOUSIN
MODEL BR627
(GC No. 32-032-22)
GAS FIRE
&
600B607/05

Advertisement

loading

Summary of Contents for Valor LIMOUSIN BR627

  • Page 1 THIS APPLIANCE IS FOR USE IN THE UNITED KINGDOM (GB) AND THE REPUBLIC OF IRELAND (IE) ONLY. This guide is intended to help you care for your Valor gas fire. Please read thoroughly before using and keep for future reference We trust that this guide gives sufficient details to enable the your appliance to be operated and maintained satisfactorily.
  • Page 2 BS EN ISO 9001 quality system accepted by the British Standards Institute. The Highest Standards Valor is a member of the Society of British Gas Industries which works to ensure high standards of safety, quality and performance. Careful Installation Valor is a CORGI registered company.
  • Page 3: Table Of Contents

    C A R E Thank you for choosing Valor. All Valor gas fires are designed to meet the most stringent quality, performance and safety requirements to provide our customers with many years’ trouble-free service. Your owner guide aims to improve your understanding and appreciation of your Valor gas fire by providing simple and informative instructions to ensure that you benefit from the excellent performance and features it has to offer.
  • Page 4: Safety

    OWNER’S GUIDE SAFETY IF YOU SMELL GAS DON’T SMOKE EXTINGUISH ALL NAKED FLAMES DON’T TURN ELECTRICAL SWITCHES ON OR OFF TURN OFF THE GAS SUPPLY AT THE METER OPEN DOORS AND WINDOWS TO GET RID OF THE GAS IMMEDIATELY CALL THE GAS EMERGENCY SERVICE – SEE YOUR LOCAL TELEPHONE DIRECTORY 1.
  • Page 5 OWNER’S GUIDE 5. The minimum height from the top of the hearth to the underside of any shelf made from wood or other combustible material and which is not more than 150mm deep is 750mm. For shelves deeper than 150mm add 12.5mm to the above clearance for every 25mm of additional shelf depth.
  • Page 6: Operating Your Fire

    OWNER’S GUIDE OPERATING YOUR FIRE Please note • When operating your fire for the first time, some vapours may be given off which may cause a slight odour and could possibly set off any smoke alarms in the immediate vicinity. These vapours are quite normal with new appliances. They are totally harmless and will disappear after a few hours use.
  • Page 7 OWNER’S GUIDE If low heat is required, release the button. The button will automatically spring up to the low heat position shown in figure 2 (See note i below). For a higher heat level slide the button upwards. The burner flames and heat output will gradually increase until the button reaches the high heat position shown in figure 2.
  • Page 8: Cleaning

    OWNER’S GUIDE CLEANING Turn the fire off and allow it to cool before attempting any cleaning. Note that the fire will retain heat for some time after it has been turned off. If large pieces of debris are found anywhere in the fireplace, have the chimney inspected before further use.
  • Page 9: Fitting The Ceramic Coals

    OWNER’S GUIDE FITTING THE CERAMIC COALS 7.1 Place the 7.4 Place front base coal two coals in the burner each side compartment so of the that it rests on centre Fig. 4 Front base coal the ledges at the loose coal. sides and front.
  • Page 10: Maintenance

    OWNER’S GUIDE MAINTENANCE Battery replacement This appliance requires 9V PP3 Ever-Ready Silver Seal (or equivalent) battery. To replace the battery remove the bottom front cover casting. Fit the new battery firmly to the connections on the generator, the positive battery terminal (+) being to the right as you insert.
  • Page 11 OWNER’S GUIDE Servicing • In the United Kingdom servicing can be carried out either by a Valor Service engineer or a CORGI registered installer. • If you require your fire to be serviced by a Valor engineer, please contact Valor Service on 0121 386 6203 and quote the following details;...

This manual is also suitable for:

Coalflame br627