Valor C1 superflame Installer's Manual page 9

Inset live fuel effect gas fire
Hide thumbs Also See for C1 superflame:
Table of Contents

Advertisement

Graph 1. Combustible shelf clearances
2.12 The minimum height from the top surface of the hearth to the underside of any
shelf made from wood or other combustible materials is shown in graph 1.
2.13 Note that soft wall coverings (e.g. embossed vinyl, etc.) are easily affected by heat.
They may scorch or become discoloured when close to a heating appliance. Please bear
this in mind when installing.
2.14 This appliance must not be installed in any room that contains a bath or shower or
where steam is regularly present.
2.15 An extractor fan may only be used in the same room as this appliance, or in any
area from which ventilation for the appliance is taken, if it does not affect the safe
performance of the appliance. Note the spillage test requirements detailed further on in
this manual. If the fan is likely to affect the appliance, the appliance must not be installed
unless the fan is permanently disconnected.
2.16 In the United Kingdom (GB) no special ventilation bricks or vents are normally
required in the room for this appliance. In the Republic of Ireland (IE) permanent
ventilation must comply with the regulations currently in force.
INSTALLER'S GUIDE
Page 9

Advertisement

Table of Contents
loading

Table of Contents