17.13 To replace the burner.

(See figure 59).
1. Remove the burner unit (See section 17.7).
2. Support the elbow injector and unscrew the
injector nut.
3. Remove the two screws from the burner clamping
plate (See figure 59)
4. Lift the right hand side of the burner, slide it to the
right and lift clear
5. Refit in reverse order.

17.14 To remove the main burner injector.

(See figure 60).
1. Remove the burner (See section 17.13).
2. Remove the burner clamping screw (See figure 60)
3. Unscrew the injector from the burner
4. Refit in the reverse order.

17.15 To remove the appliance from the fireplace.

1. Remove the burner unit (See section 17.7).
2. If the fire retention is as method 1 (See section 9.1 of
this guide), remove the screws.
If the fire retention is as method 2 (See section 9.2 of
this guide), slacken the hexagonal adjusters on the cable
retainers and unscrew the thumbscrews to release the
cables.
3. Refit as described in the relevant installation sections. Make sure gas soundness,
sealing, spillage test and performance are satisfactory.
©
GDC Group Ltd. 2011
INSTALLER GUIDE
Page 47
Figure 59. Removal of burner
Figure 60. Main burner
injector removal