Operating Instructions UPster H 500 / H 500S
Par.
Configuration
no.
options
119 IR communication
120
Load factory set-
ting service pa-
rameters
201
Machine type
202
Setpoint tank
temperature
203
Pre-rinse time
204
Rinse time
205
Indication of ope-
ration
218
Shortage of rinse
aid
219
Shortage of de-
tergent
224
Power supply
mode rinse aid
dosing pump
225
Detergent dosing
pump activation
mode
9735020
Use as
Value range Unit
Parameters
0/1
Parameters
0/1
Parameters
103
Parameters
10 ... 82
Parameters
0 ... 8
Parameters
4.0 ... 25.0
Parameters
0 ... 10
Parameters
0/1
Parameters
0/1
Parameters
0 ... 3
Parameters
0 ... 3
Design and construction subject to change without prior notice!
Page
-
It is possible to shut off communica-
tion via IR interfaces. (0)
-
Effective only upon power supply
reset ON/OFF
Caution! All changes to service
parameters will be reversed.
Power supply reset must be carried
out within 5 minutes, otherwise fac-
tory settings will not be loaded.
Without power supply reset, the
information 123 will be displayed.
-
Setting for UPster
°C
Standard for all the rinse programs
on one appliance! Output dependent
on definition
Sec.
See pre-rinse process step
Sec.
Duration of final rinse time, running
time limited by P306!!
-
Definition of the information which is
to be switched via the potential-
free contact
0 – no information
1 – filling/Heating, ready for wash-
ing/washing or draining
2 – filling/Heating, ready for wash-
ing/washing
3 – filling / Heating
4 – ready for washing
5 – washing
6 – draining
7 – error
8 – not status machine OFF and
draining
9 – EW active
10 – not status Machine OFF
-
Monitoring
Display
-
Monitoring
Display
-
Definition: Energizing rinse aid
pump:
0 – no signal
1 – energizing according to calculat-
ed running time
2 – energize as final rinse
3 – energize as wash pump
-
Definition energizing detergent
pump:
0 – no signal
1 – energizing according to calculat-
ed running time
2 – energize as final rinse
3 – activate as per wash pump