Operating Instructions UPster H 500 / H 500S
9735020
17
Settings / modifications / on-site adaptation
17.1 Using the keyboard for programming
Increase value /
move forward
value/scroll back
Function field
Value field
Access codes for various user-levels have been defined. When the complete code has
been entered, it is compared to an internal code table. The corresponding user level is
then granted depending on the code that has been entered. 2 access codes are available
for each user level; the first is for restricted access, i.e. no modification of parameters is
possible (viewing mode), and the second gives access to the entire range of functions
(viewing and modification).
This is described briefly in the short programming instructions that accompany every
warewashing machine.
For control programming, the power supply must be available but the machine must be
completely switched off (no LED must be illuminated).
Code input:
View service data:
Modify service data:
View configuration data:
View dosing technology data:
Modify dosing technology data:
17.2 Code input
To access code input mode, hold down the "0" key (for about 3 seconds) until you see
Pressing the "0" key again lets you quit programming at any time.
The digit to be modified will flash.
Press the "I" key to increase the value/code indicated on the display unit, or press the "II"
key to decrease it, or press the "accept" key to save it. The next value will then flash and
will be the only one visible.
Design and construction subject to change without prior notice!
Page
Decrease
Accept / modify
CODE 10000
CODE 10001
CODE 20000
CODE 40000
CODE 40044
in the display.
24
42
of
Exit / Start
Programming