Appendix 4
The buffer memory is used to exchange data between the FX5-ENET and the CPU module or external devices.
Buffer memory values are set to their defaults (initial values) when the system is powered off or the CPU module is reset.

List of buffer memory addresses

Buffer memory address
Decimal
Hexadecimal
29
1DH
30
1EH
31
1FH
34
22H
36
24H
50 to 51
32H to 33H
52 to 53
34H to 35H
54 to 55
36H to 37H
56
38H
57
39H
58
3AH
59
3BH
60
3CH
61
3DH
62
3EH
64 to 65
40H to 41H
74 to 75
4AH to 4BH
76 to 77
4CH to 4DH
102 to 104
66H to 68H
108 to 139
6CH to 8BH
152 to 153
98H to 99H
154 to 155
9AH to 9BH
156 to 157
9CH to 9DH
158
9EH
159
9FH
201
C9H
202 to 204
CAH to CCH
205 to 207
CDH to CFH
300, 301
12CH, 12DH
304, 305
130H, 131H
308, 309
134H, 135H
312, 313
138H, 139H
316, 317
13CH, 13DH
320 to 351
140H to 15FH
352 to 383
160H to 17FH
416 to 447
1A0H to 1BFH
480 to 511
1E0H to 1FFH
544 to 575
220H to 23FH
1000 to 1127
3E8H to 467H
1256 to 1383
4E8H to 567H
2000 to 3023
7D0H to BCFH
3024 to 4047
BD0H to FCFH
4100 to 4101
1004H to 1005H
4104 to 4105
1008H to 1009H
4112
1010H
APPX
136

Appendix 4 Buffer Memory

Buffer Memory
Name
Latest error code
Module information
Firmware version
Input signals
Output signals
IP address setting
Subnet mask pattern setting
Default router IP address setting
IP address storage area write request
IP address storage area write status
IP address storage area clear request
IP address storage area clear status
IP address change function enable flag
IP address storage area write error code
IP address storage area clear error code
IP address
Subnet mask pattern
Default gateway IP address
Ethernet address (MAC address)
Error code
Open completion signal
Open request signal
Socket communications receive status signal
Initial status
Initial error code
Same IP address state storage area
MAC address of the already connected station
MAC address of the station connected later
"Communication start at request" request
Periodic communication stop request
Periodic communication restart request
Execution Status flag
Ready
System area
Simple CPU communication status
Simple CPU error code
Abnormal response code
Execution interval (current value)
Remote input (RX)
Remote output (RY)
Remote register (RWr)
Remote register (RWw)
Cyclic transmission status of each station
Data link status of each station
Total number of connected stations
Initial value
Read, write
0
Read
69A0H
Read
*1
Read
0
Read, write
0
Read, write
0.0.0.0
Read, write
0.0.0.0
Read, write
0.0.0.0
Read, write
0
Read, write
0
Read
0
Read, write
0
Read
0
Read
0
Read
0
Read
192.168.3.251
Read
255.255.255.0
Read
0.0.0.0
Read
*2
Read
0
Read
0
Read
0
Read
0
Read
0
Read
0
Read
0.0.0.0
Read
0.0.0.0
Read
0.0.0.0
Read
0
Read, write
0
Read, write
0
Read, write
0
Read
0
Read
0
Read
0
Read
0
Read
0
Read
0
Read
0
Read, write
0
Read
0
Read, write
0
Read
0
Read
0
Read