Mitsubishi Electric MELSEC iQ-F Series User Manual page 128

Hide thumbs Also See for MELSEC iQ-F Series:
Table of Contents

Advertisement

Event
Event
code
type
1910
System
1911
System
1912
System
1E10
System
1E11
System
1E12
System
1E13
System
1E14
System
1F00
System
2160
System
2C80
System
2C81
System
2C82
System
2CF0
System
2DA0
System
2DA1
System
2DA2
System
2DA3
System
2DA4
System
2DA5
System
2DA6
System
2DA7
System
2DA8
System
2DA9
System
2DAA
System
2DAB
System
2DB0
System
3030
System
3056
System
3060
System
3061
System
3062
System
10 TROUBLESHOOTING
126
10.7 List of Event Code
Event
Event
Detected event
category
status
Error
Minor
Flash memory check error (E-mail setting
change function sector)
Error
Minor
Flash memory check error (DNS setting change
function sector)
Error
Minor
Flash memory check error (MQTT setting
change function sector)
Error
Minor
EtherNet/IP communication error
Error
Minor
EtherNet/IP communication error
Error
Minor
EtherNet/IP communication error
Error
Minor
EtherNet/IP communication error
Error
Minor
EtherNet/IP communication error
Error
Minor
MELSOFT connection error
Error
Moderate
IP address duplication detection
Error
Moderate
Receive parameter sum value error
Error
Moderate
Receive parameter data error
Error
Moderate
Divided parameter receive error
Error
Moderate
FX5-ENET WDT error occurs.
Error
Moderate
Connection setting parameter (Error in the
number of connection setting)
Error
Moderate
Connection setting parameter (Connection
number error)
Error
Moderate
Connection setting parameter (Communication
destination communication method error)
Error
Moderate
Connection setting parameter (Protocol system
error)
Error
Moderate
Connection setting parameter (Open system
error)
Error
Moderate
Connection setting parameter (Fixed buffer
transmitting method error)
Error
Moderate
Connection setting parameter (IP address
(IPv4) error)
Error
Moderate
Connection setting parameter (IP address
(IPv6) error)
Error
Moderate
Connection setting parameter (Existence
confirmation specification error)
Error
Moderate
Connection setting parameter (Communication
data code error)
Error
Moderate
Connection setting parameter (Error in
specification of writing during running)
Error
Moderate
Connection setting parameter own node port
number error
Error
Moderate
Request data error
Error
Moderate
Specific code error
Error
Moderate
Socket communication buffer full
Error
Moderate
The total number of connection is outside the
range. (Configuration setting parameter)
Error
Moderate
The station number is outside the range.
(Configuration setting parameter)
Error
Moderate
The number of occupied stations is outside the
range. (Configuration setting parameter)
Detailed information
Detailed
Detailed
information 1
information 2
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Detailed
information 3
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-f fx5-enetFx5-u-enet-e09r736

Table of Contents