Install the UltraGlide Sensors

Boom Sensor Mounting Locations

Sensor mounting locations may be influenced by the boom configuration. Determine the appropriate location
for mounting sensors on the boom, ensuring the sensors will not interfere with or be damaged by folding or
unfolding the booms. The sensor should be mounted outside of the boom fold, but inside the boom breakaway.
Mount the UltraGlide Boom Sensors
Note:
When mounting two sensors per boom, the inside sensor must be turned sideways to prevent the
sensors from interfering when folding the booms.
Boom Sensor Mounting Location
FIGURE 5.
Secure the right sensor (P/N 063-0130-012) to the front of the right boom using two 2-1/2" ID x 3.12" L x
1.
3/8" thread zinc plated clamp U-bolts (P/N 435-3003-046).
Tighten the nuts to ensure the sensor is mounted securely.
2.
Repeat the steps above to install the remaining boom sensor(s).
3.
Manual No. 016-0230-081
WARNING
The machine must remain stationary and
switched off, with the booms unfolded and
supported, during installation or maintenance.
UltraGlide
35