Operation and maintenance
March 2023
6.2 

View measurement data

Procedure
1. Select Overview.
2. Optional: Select Service Tools → Variables.
6.2.1 
Interpret measurement status
A "Good" or "Bad" status next to a value is an indication of the reliability or integrity of the
data being received, not an indication of whether or not the value is within the configured
upper or lower ranges. A value that triggers an alert, such as a high or low temperature
indication, will change the overall status of the device, but the measurement might still be
indicated as "Good" if the reliability of the data is good.
6.3 

Check device status

The device reports diagnostic alerts when there is a device malfunction.
Procedure
1. Go to the Overview screen to view the overall device status.
2. If status is anything other than Good, select the button in the device status image to
Related information
Diagnostic messages per NAMUR NE 107
38
Figure 6-1: Overview Screen in AMS Device Configurator
open a window with Active Alerts.
Active Alerts can also be obtained via Service Tools → Alerts.