Output port [Write Only 
 
Control Register #75(0x4b) (control_reg [75]:)
Bit 
Function 
Bit 7 
 
Bit 6 
 
Bit 5 
 
Bit 4 
 
Bit 3 
 
Bit 2 
Select Max 
Range 
Bit 1 
Select Range 
Criteria 
Bit 0 
Select Second 
Return 
 
Notes 
Range Processing Criteria for two echoes:​   Max signal, Max/Min Range. 
 
Control Register #76(0x4c) (control_reg [76]:) 
 
Notes 
Peak Value of 2nd largest pulse in the signal correlation record [Read Only] 
 
Control Register #79 (0x4f) (control_reg[79]:) 
 
Notes 
Software Version:​   Revisions begin with 0x01 
 
Control Register #81(0x51) (control_reg [81]:)
Bit 
Function 
Bits 4­7 
Stop 
Address 
LIDAR­Lite v1 "Silver Label" Manual​ ,  Updated: 08/13/15  
Notes 
 
 
 
 
 
"1" selects the longer distance; "0" selects the shorter distance 
"1" selects return data based on distance; "0" selects strongest return, 
regardless of distance 
Controls echo processing selection :"1" switches to alternative return; "0" 
Selects data associated with detection criteria 
Notes 
Value in the range from 0x00­0x0f – stopping point in correlation record 
 
 