Garmin LIDAR-Lite v1 Silver Label Operating Manual page 45

Advertisement

Bit 7 
Eye Safe 
Bit 6 
Signal 
Invalid 
Bit 5 
Timestamp 
Bit 4 
Second 
Peak 
Bit 3 
PIN Status 
Bit 2 
Sig Overflow  Overflow detected in correlation process associated with a signal 
Bit 1 
Ref 
Overflow 
Bit 0 
Busy 
 
Control Register #73(0x49) (control_reg [73]:) 
 
Notes 
Measured DC value out of correlation sampler input [Read Only]:​    Value based on the ratio of 
1's and 0's 
 
Control Register #74(0x4a) (control_reg [74]:)
Bit 
Function 
Bit 7 
 
Bit 6 
 
Bit 5 
 
Bit 4 
Busy Flag 
Bit 3 
Detector 
sel 
Bit 2 
Preamp 
gain 
Bit 1 
xmt 2 en 
Bit 0 
xmt 1 en 
LIDAR­Lite v1 "Silver Label" Manual​ ,  Updated: 08/13/15  
Indicates that eye safety average power limit has been exceeded and 
power reduction is in place 
Signal Invalid – "1" No signal detected, "0' signal detected 
Active between velocity measurement pairs 
Indicates a second peak was detected. 2nd peak value compared to noise 
floor 
Indicates the state of the Mode Select external pin.  De­bounced, masked 
from output signals, inverted 
acquisition 
Overflow detected in correlation process associated with the reference 
acquisition 
Busy, indicates that the processor is actively performing an acquisition 
process. 
Notes 
 
 
 
Busy flag outputs on mode select pin with I2C initiated acquisition.  High 
causes pin output to be driven low 
Select receiver detector 1 or 2 – not used in LIDAR­Lite product 
Selects high 2x or low gain 1x setting  – not used in LIDAR­Lite product 
Enables transmit channel 2 high­side current source 
Enables transmit channel 1 high­side current source 
 