Control Register #66 (0x42) (control_reg[66]:) 
 
Notes 
Preamp DC control:​    Range 0­255 
Used in DC compensation servo loop 
Control Register #67 (0x43) (control_reg[67]:)
Bit 
Description 
Not Used 
Bits 4­7 
Bits 0­3 
Signal power level control 0x0­0xf 
 
Notes 
Transmit power control: ​ L aser drive control bits (7 through 4) ref, bits (3 through 0) signal. 
Maximum value set at factory 3amps.  The maximum output power of the optical source is set 
through a factory selected resistor which limits available current to the transmit source. 
When using laser devices, which have a much higher operating current, do not increase the 
reference control level beyond the factory settings. 
Increasing the reference control level may cause premature failure of the internal reference diode. 
 
Control Register #68 (0x44) (control_reg[68]:) 
 
Notes 
Processing range gate (low byte):​   Sets the starting location for range processing in the 
correlation 
 
Control Register #69 (0x45) (control_reg[69]:) 
 
Notes 
Processing range gate (high byte) 
 
Control Register #70(0x46) (control_reg [70]:) 
 
Notes 
Single bit passed from microcontroller PWM output:​    High at mode pin returns pulse width 
proportional distance 
 
Control Register #71 (0x47) ­ Mode/Status (control_reg[71]:)
Bit 
Function 
LIDAR­Lite v1 "Silver Label" Manual​ ,  Updated: 08/13/15  
Notes 
 
 