Preamp Off : Shutdown preamp between measurements
●
CLK SHUT : External Clock Shutdown – Not used in standard LIDARLite
●
FPGA SLEEP : Full FPGA sleep after measurement
DET OFF : Turns off detector bias after measurement
●
N/A: Not used presently
●
Velocity Scale factor: "1" sets the velocity measurement separation to 10msec resulting in a
●
velocity calibration in meters/sec. A "0" value results in a measurement separation of 100msec.
●
Inhibit Reference : If "1" inhibits the acquisition of reference pulses reducing measurement times
and reducing measurement variations at the expense of decreasing accuracy over time. "0" allows
normal operation
●
Velocity: Enable velocity measurement
Control Register #5 (0x05) (control_reg[5]:)
Notes
●
Nominal 128
●
Measured DC value out of correlation sampler input. Value based on the ratio of 1's and 0's (read
only) preamp
●
Parameter used as part of health flag criteria
Control Register #6 (0x06) (control_reg [6]:)
Notes
[Read Only]: High byte of calculated delay of reference– calculated after correlation record
●
processing
Control Register #7 (0x07) (control_reg [7]:)
Notes
●
[Read Only]: Low byte of calculated delay of reference– calculated after correlation record
processing
Control Register #8 (0x08) (control_reg [8]:)
Notes
●
Correlation Peak value reference [Read Only]: (scaled to 0 – 0xff max peak value) – Parameter
used as part of health flag criteria