Download Print this page

Garmin LIDAR-Lite v1 Silver Label Operating Manual page 39

Advertisement

Preamp Off​ :  Shutdown preamp between measurements 
CLK SHUT​ :  External Clock Shutdown – Not used in standard LIDAR­Lite 
FPGA SLEEP​ :  Full FPGA sleep after measurement 
DET OFF​ :  Turns off detector bias after measurement 
N/A:​    Not used presently 
Velocity Scale factor:​   "1" sets the velocity measurement separation to 10msec resulting in a 
velocity calibration in meters/sec. A "0" value results in a measurement separation of 100msec. 
Inhibit Reference   :​   If "1" inhibits the acquisition of reference pulses reducing measurement times 
and reducing measurement variations at the expense of decreasing accuracy over time. "0" allows 
normal operation 
Velocity:​   Enable velocity measurement 
Control Register #5 (0x05) (control_reg[5]:) 
 
Notes 
Nominal 128 
Measured DC value out of correlation sampler input.  Value based on the ratio of 1's and 0's  (read 
only) preamp 
Parameter used as part of health flag criteria 
 
Control Register #6 (0x06) (control_reg [6]:) 
 
Notes 
[Read Only]:​   High byte of calculated delay of reference– calculated after correlation record 
processing 
 
Control Register #7 (0x07) (control_reg [7]:) 
 
Notes 
[Read Only]:​   Low byte of calculated delay of reference– calculated after correlation record 
processing 
 
Control Register #8 (0x08) (control_reg [8]:) 
 
Notes 
Correlation Peak value reference [Read Only]:​   (scaled to 0 – 0xff max peak value) – Parameter 
used as part of health flag criteria 
 
LIDAR­Lite v1 "Silver Label" Manual​ ,  Updated: 08/13/15  