Bleeding rear wheel circuit
Open rear wheel circuit reservoir (1).
e
Attention:
To prevent brake fluid from entering the connector,
do not release the ABS pressure modulator plug
connections.
Draw off the old brake fluid from the wheel circuit
reservoir.
Remove rear brake pads.
e
Attention:
Only use the piston reset
device, BMW No. 34 1 531, if the wheel circuit res-
ervoir cover is open.
34 1 536
Use the adapter, BMW No. 34 1 536, instead of
the external brake pad.
With the handle outwards, use the reset
device, BMW No. 34 1 531, on the rear brake
caliper to press back the pistons completely and
to position them.
Wrap a cloth around the brake caliper.
Connect the brake bleeding device to the bleed
screw, but do not switch it on.
Switch on the ignition.
34.16
L
After switching on the ignition, always wait for the
BMW Integral ABS to complete its self-diagnosis.
Do not operate the brake lever until self-diagnosis
has completed.
1
R28340110
34 1 531
R28000170
Note:
Gently press the footbrake until the pump just
starts up.
Open the bleed screw.
Drain wheel circuit using a pump.
Close the bleed screw.
Release the brake and switch off the ignition.
Disconnect the brake bleeding device from the
bleed screw.