OM3006.3 04/98
Instrument Panel and Indicators
4. Pressing the Lamp Test switch to the bottom (''√'')
again will advance to the next fault code (if more
than one code is present). Once all active fault
codes have been displayed, the fault code display
sequence will be repeated, starting from the first
fault code.

Exiting The Diagnostics Mode

Starting the engine or turning the keyswitch to the OFF
position will EXIT the diagnostics fault flash mode.
If active fault codes have been determined as de-
scribed previously, refer to the Cummins Engine Cen-
try™ ™ System ''Troubleshooting and Repair Manual'',
Bulletin No. 3666070, or contact an Authorized Repair
Location.