Komatsu 530M Operation & Maintenance Manual page 131

Dump truck
Table of Contents

Advertisement

Optional Equipment - Section 6
Page 6-16
DISPLAYS AT START-UP
POWER ON:
ALL external display lamps (Figure 6-2) will come on
and stay on for approximately 27 seconds during the
''Power-up Process''.
The ''Power-up Process'' will display the PLM settings.
Each display will occur for approximately 3 seconds:
1. The display will show:
In addition, a buzzer will sound and the following
lamps will light for 3 seconds:
•Reception Pilot Lamp (2, Figure 6-1)
•Transmission Pilot Lamp (3, Figure 6-1)
•Memory Card Pilot Lamp (4, Figure 6-1)
2. The display will show:
The ''xx'' indicates the Truck Model. Refer to
"Initial Setup of Payload Meter" for code defini-
tions.
3. The display will show:
This display indicates the status of
the Memory Card where:
''Cd : - -'' indicates Card Not Used, and
''Cd : oo'' indicates Card Is Used.
4. The display will show:
This display indicates the status of
the Inclinometer for the PLM,
where
''CL : - -'' indicates Inclinometer Not Used, and
''CL : oo'' indicates Inclinometer Is Used.
5. The display will show:
This display indicates method of
measurement where:
"US : - -" indicates METRIC Tons.
"US : oo" indicates U.S. Tons.
6. The display will show:
This function is not used.
"SU : - -" indicates Switch 8 is up.
"SU : oo" indicates Switch 8 is down.
7. The display will show:
This display indicates the Machine ID code where
''xxx'' indicates a value between 0 and 200.
8. The display will show:
This display indicates the Operator ID code where
''xxx'' indicates a value between 0 and 200.
9. The display will show:
This display indicates the Speed Limit setting
where ''xx'' indicates a value between 0 and 99
km/h.
10. The display will show:
This display indicates the Option code setting.
Refer to ''Operator Check Mode, Setting the Op-
tion Code'' and to ''Method of Operation'' for more
information on this function.
NORMAL OPERATION
If the truck engine is started before the preceding
''Power-up Process'' is completed, the display will shift
to normal operation.
If the engine is running when the payload meter starts
up, only "o:XXX" and "d:XXX" will display before
switching to normal operations.
OM6007 2/99