Optional Equipment - Section 6
Page 6-14
5. Press the MODE switch once.The
display will show. Refer to "Setting
The Operator ID" on Page 18 to change operator.
6. Press the MODE switch once. The
display will show."SP:62" should be
displayed. The speed limit should
be set to 62 to avoid unnecessary faults and
warnings. Refer to "Setting The Speed Limit" on
Page 17 to make adjustments.
7. Press the MODE switch once.
The display will show. Refer to
"Setting The Option Code" on
Page 17 to change the option.
8. Press the MODE switch once.
The current time should be dis-
played with the minutes flashing.
Refer to "Setting The Time And Date" on Page 18
to change the time and date.
9. Push the MODE switch to return to normal opera-
tion.
Checking the Service Check Mode
Refer to Pages 23 and 24 for additional information
on UP Factor and PL Modeprior to setting these
values.
Setting "UP:00"
1. Press and hold the LIGHT/INC and
MODE switches. The display will
show.
2. Press and hold the LIGHT/INC and
TOTAL/SFT switches. The display
will show.
3. Press the CAL/CLR switch once.
The display will show.
4. Press the LIGHT/INC switch until
"UP: 0" is displayed. ONLY "UP:
0" IS RECOMMENDED.
5. Press MODE. The display will
show.
6. Press MODE and the meter will return to normal
operation.
Setting "PL:00"
1. Press and hold the LIGHT/INC and MODE
switches. The display will show.
2. Press and hold the LIGHT/INC and TOTAL/SFT
switches.
The display will show.
3. Press the CAL/CLR switch once.
The display will show.
4. Press the CAL/CLR switch once.
The display will show.
5. Press the LIGHT/INC switch until
"PL:00" is displayed. ONLY
"PL:00" IS RECOMMENDED.
6. Press the MODE switch.
The display will show.
7. Press MODE and the meter will return to normal
operation.
Checking the G
setting
T
The G
value must be set = 1.000. Refer to "Calculation
t
Method" on Page 8 for display and adjustment infor-
mation.
Checking the Inclinometer Settings
Refer to "Calculation Method" for instructions to dis-
play truck pitch angle. With truck on level ground,
properly charged suspensions, and empty the display
should indicate 0.0± 1.0. Remember this is not a live
display. After adjustment, Service Check Mode must
be entered again to obtain a new reading.
An alternative method is to use a Personal Computer
running the Komatsu Payload Download Program for
windows. The "Monitor Pressures" section of the pro-
gram displays live inclinometer data. The inclinometer
can be loosened and adjusted until the live display
shows 0.0± 1.0 degrees with the truck on level ground,
properly charged suspensions, and empty.
Another method is to use a voltmeter to read the
voltage output of the inclinometer. With the truck on
level ground, properly charged suspensions, and
empty, the output voltage should be 2.6± .1 volts.