Control Panel And Console Terminal Port - DEC AlphaServer 8200 Installation Manual

Hide thumbs Also See for AlphaServer 8200:
Table of Contents

Advertisement

1.
Unpack the VT510 console terminal. The console terminal signal cable
is shipped in the loose piece box and consists of a 17-01364-02 cable
and H8575-A adapter.
2.
Open the front door and connect one end of the 17-01364-02 cable to
the console terminal port on the control panel. Connect the cable
ground wire to the cabinet grounding screw nearby (see Figure 4-2).
Connect the other end of the cable to the H8575-A, which connects to a
25-pin D-subminiature connector on the console terminal. Connect the
other end of the cable ground wire to one of the screws on the H8575-
A.
3.
If a printer is not present, skip this step. Otherwise, unpack the
printer. Connect the BC16E-25 signal cable to the printer and to the
console terminal. Plug in the printer.
4.
The following are the default terminal characteristics. If the terminal
does not have these characteristics, they must be set accordingly:
Baud rate = 9600 (transmit = receive)
8 bits, no parity
1 Stop Bit
Xoff at 64
Figure 4-2

Control Panel and Console Terminal Port

Expander
PowerComm 3
Front
PowerComm 2
PowerComm 1
Making Console, SCSI, Ethernet, FDDI, and DSSI Connections 4-3
Console
External
Enable (XMI/FBUS)
External
UPS Power
External
Power Enable
BX-0446-95
Possible
ground
screws