Gamma Function; To Use The Gamma Function - JAI GOX-5105M-5GE User Manual

Cmos digital progressive scan monochrome and color camera with gige interface
Table of Contents

Advertisement

GOX-5105MC-5GE | GOX-8105MC-5GE | GOX-12405MC-5GE | GOX-16205MC-5GE | GOX-20405MC-5GE | GOX-24505MC-5GE

Gamma Function

Related Setting Items:
The Gamma function corrects the output signals from the camera beforehand (reverse correction),
taking into consideration the light-emitting properties of the monitor display. As the light-emitting
properties of the monitor are not linear, the entire image may be darker or the gradation in the dark
areas may be less noticeable when camera outputs are displayed without processing.
The Gamma function can be used to correct the camera signals with an opposite-direction curve and
produce a display that is close to linear.

To Use the Gamma Function

Configure the settings as follows.
Item
Gamma
0.45, 0.5, 0.55, 0.6, 0.65, 0.75, 0.8, 0.9, 1.0
LUTMode
Gamma
Note: You can use the LUT function to configure a curve with more detailed points. For details,
see
LUT (Lookup
Table).
AnalogControl
Setting Value / Selectable Range
User Manual (Ver. 1.0) - Main Functions
Select the Gamma correction value.
Use Gamma.
- 83 -
Description

Advertisement

Table of Contents
loading