GOX-5105MC-5GE | GOX-8105MC-5GE | GOX-12405MC-5GE | GOX-16205MC-5GE | GOX-20405MC-5GE | GOX-24505MC-5GE
LUT (Lookup Table)
Related Setting Items:
The LUT function is used to generate a non-linear mapping between signal values captured on the
sensor and those that are output from the camera. You can specify the output curve using 257 setting
points (indexes).
To Use the LUT Function
Configure the settings as follows.
Setting Value /
Item
Selectable Range
LUTSelector
Red, Green, Blue
LUTIndex
0 ~ 256
LUTValue
0 ~ 4095
LUT Value
LUT values range from 0 at the lowest to 4095 at the highest. Linear interpolation is used to calculate
LUT values between the index points.
LUTControl
Select the LUT channel to control (Color models only).
Select the LUT index to configure. Indexes represent the possible
pixel values captured on the sensor, from the lowest value (Index 0) to
the highest (Index 256).
For example, Index 0 represents a full black pixel and Index 256
represents a full white pixel.
Set the LUT output value for the selected index.
User Manual (Ver. 1.0) - Main Functions
Description
- 84 -