JAI GOX-5105M-5GE User Manual page 136

Cmos digital progressive scan monochrome and color camera with gige interface
Table of Contents

Advertisement

GOX-5105MC-5GE | GOX-8105MC-5GE | GOX-12405MC-5GE | GOX-16205MC-5GE | GOX-20405MC-5GE | GOX-24505MC-5GE
Digital IO Control
Setting
Item
Range
LineSource
LineFormat
LineStatusAll
Default
Value
Select the line source signal for the item selected in LineSelector.
0: Off (Only when LineSelector is set to TimestampReset)
1: AcquisitionActive
2: FrameActive
4: ExposureActive
5: FVAL
7-10: PulseGenerator0-3
11-14: UserOutput0-3
15-18: Action0-3 (only when LineSelector=TimestampReset)
24: Line5 Opt In1
36: Nand0 Out
-
-
37: Nand1 Out
40: - (Not selectable for Output and NAND In)
41: Low
42: High
43: AcquisitionTriggerWait
44: FrameTriggerWait
※LineSelector=24 is fixed to "-".
Default
LineSelector=TimestampReset: Off(0)
LineSelector=Other than TimestampReset: Line5 Opt In1 (24)
Display the signal format.
2: TTL
5: OptoCoupled
-
-
7: Internal Signal
Default
LineSelector=21,24: OptoCoupled
LineSelector=53,54,55,56,63: Internal Signal
Display the input/output signal status. The state is shown with 16 bits. Bit
assignments are as follows.
bit0: Unused (Fixed to 0)
bit1: Line2
bit2 - 3: Unused (Fixed to 0)
-
-
bit4: Line5
bit5 - 11: Unused (Fixed to 0)
bit12: Nand0 In1
bit13: Nand0 In2
bit14: Nand1 In1
bit15: Nand1 In2
Description