Miscellaneous; Troubleshooting; Power Supply And Connections; Image Display - JAI GOX-5105M-5GE User Manual

Cmos digital progressive scan monochrome and color camera with gige interface
Table of Contents

Advertisement

GOX-5105MC-5GE | GOX-8105MC-5GE | GOX-12405MC-5GE | GOX-16205MC-5GE | GOX-20405MC-5GE | GOX-24505MC-5GE

Miscellaneous

Troubleshooting

Check the following before requesting help. If the problem persists, contact your local JAI distributor.

Power Supply and Connections

Issue: The POWER/TRIG LED remains lit amber and does not turn green, even after power is
supplied to the camera.
Cause and Solution:
Camera initialization may not be complete due to a lack of power. Check the 6-pin power cable
l
connection.
Or the GigE connection may be not established. Check the ethernet cable connection.

Image Display

Issue: Gradation in dark areas is not noticeable.
Cause and Solution: Use the gamma function to correct the display. As the light-emitting properties
of the monitor are not linear, the entire image may be darker or the gradation in the dark areas may be
less noticeable when camera outputs are displayed without processing. Using the gamma function
performs correction to produce a display that is close to linear. For details, see

Settings and Operations

Issue: Settings cannot be saved to user memory.
Cause and Solution: You cannot save to user memory while images are being acquired by the
camera. Stop image acquisition before performing the save operation.
Issue: I want to restore the factory default settings.
Cause and Solution: Load Default under User Set Selector in the Feature Properties tab to restore
the factory default settings.
User Manual (Ver. 1.0) - Miscellaneous
- 158 -
Gamma
Function.