9
8
LED Description
1-3
1
Host 12Gb SAS
Link Status/
Link Activity
2
OK
3
Fault
4
OK to Remove
5
Identify
4
6
Cache Status
7
Network Port Activity Status
8
Network Port Link Speed
9
Expansion Port Status
1-Cables must be qualified HD mini-SAS cable options.
2-Use a qualified SFF-8644 to SFF-8644 cable option when connecting the controller to a 12Gb SAS HBA.
3-Use a qualified SFF-8644 to SFF-8088 cable option when connecting the controller to a 6Gb SAS HBA.
4-Cache Status LED supports power on behavior and operational (cache status) behavior. See also
5-When port is down, both LEDs are off.
Figure 21 LEDs: 5005/4005 Series SAS controller module (HD mini-SAS)
NOTE: Once a Link Status LED is lit, it remains so, even if the controller is shut down via the SMC or the CLI.
7
Definition
Green — The port is connected and the link is up.
Amber — Partial link exists (one or more lanes down).
Blinking green or amber — Host link activity is detected.
Green — The controller is operating normally.
Blinking green — System is booting.
Off — The controller module is not OK, or is powered off.
Off — The controller is operating normally.
Amber — A fault has been detected or a service action is required.
Blinking amber — Hardware-controlled power-up or a cache flush or
restore error.
Off — The controller is not prepared for removal.
Blue — The controller module is prepared for removal.
White — The controller module is being identified.
Green — Cache is dirty (contains unwritten data) and operation is normal.
The unwritten information can be log or debug data that remains in the
cache, so a Green cache status LED does not, by itself, indicate that any
user data is at risk or that any action is necessary.
Off — In a working controller, cache is clean (contains no unwritten data).
This is an occasional condition that occurs while the system is booting.
Blinking green — A CompactFlash flush or cache self-refresh is in
progress, indicating cache activity.
See also
"Cache Status LED details" (page
5
Off — The Ethernet link is not established, or the link is down.
Green — The Ethernet link is up (applies to all negotiated link speeds).
5
Off — Link is up at 10/100base-T negotiated speeds.
Amber — Link is up and negotiated at 1000base-T.
Off — The port is empty or the link is down.
Green — The port is connected and the link is up.