Operator's (Ops) Panel - Seagate RealStor 5005 Series Hardware Installation

Hide thumbs Also See for RealStor 5005 Series:
Table of Contents

Advertisement

At the rear, the chassis assembly can hold a maximum of two PCMs and two SBB-compliant IOMs.
IMPORTANT: The RealStor enclosures support SBB dual-controller configuration only. Single-controller support is provided
only when a controller fails over to its partner controller. For RBODs and EBODs, an IOM must be installed in each IOM slot to
ensure sufficient air flow through the enclosure during operation.
Figure 14 2U12 enclosure chassis – dimetric front orientation
Figure 15 2U24 enclosure chassis – dimetric front orientation
NOTE: Either 2U chassis can be configured as a controller enclosure or as an optional expansion enclosure for adding
storage.

Operator's (Ops) panel

The enclosure front panel has an Operator's (Ops) panel mounted on the left ear flange. A flexible cable connects the Ops
panel to the midplane. The Ops panel is a passive component: the midplane controls the panel, and the IOMs control all
Operator's (Ops) panel
23