b. Enter the default password !manage.
If the default user or password—or both—have been changed for security reasons, enter the secure login credentials
instead of the defaults shown above.
7. At the prompt, enter the following CLI command to set the values you obtained in
for controller A, and then for controller B:
set network-parameters ip address netmask netmask gateway gateway controller a|b
where:
address is the IP address of the controller
netmask is the subnet mask
gateway is the IP address of the subnet router
a|b specifies the controller whose network parameters you are setting
For example:
# set network-parameters ip 192.168.0.10 netmask 255.255.255.0 gateway 192.168.0.1 controller a
# set network-parameters ip 192.168.0.11 netmask 255.255.255.0 gateway 192.168.0.1 controller b
8. Enter the following CLI command to verify the new IP addresses:
show network-parameters
Network parameters, including the IP address, subnet mask, and gateway address are displayed for each controller.
9. Use the ping command to verify connectivity to the gateway address.
For example:
# ping 192.168.0.1
A success message will say that the remote computer responded with 4 packets.
10. In the host computer's command window, type the following command to verify connectivity, first for controller A and
then for controller B:
ping controller-IP-address
If you cannot access your system for at least three minutes after changing the IP address, you might need to restart
the Management Controller(s) using the serial CLI.
When you restart a Management Controller, communication with it is temporarily lost until it successfully restarts.
Enter the following CLI command to restart the Management Controller in both controllers:
restart mc both
IMPORTANT: When configuring an iSCSI system or a system using a combination of FC and iSCSI SFPs, do not
restart the Management Controller or exit the terminal emulator session until configuring the CNC ports as
described in
11. When you are done using the CLI, exit the emulator.
12. Retain the IP addresses (recorded in
NOTE: Using HyperTerminal with the CLI on a Microsoft Windows host:
On a host computer connected to a controller module's mini-USB CLI port, incorrect command syntax in a HyperTerminal
session can cause the CLI to hang. To avoid this problem, use correct syntax, use a different terminal emulator, or connect
to the CLI using telnet rather than the mini-USB cable.
Be sure to close the HyperTerminal session before shutting down the controller or restarting its Management Controller.
Otherwise, the host's CPU cycles may rise unacceptably.
50
Installation
"Change the CNC port mode" (page
step
1) for accessing and managing the controllers using the SMC or the CLI.
51).
step 1