A Technical Specifications; Enclosure Dimensions; Enclosure Weights; Environmental Requirements - Seagate RealStor 5005 Series Hardware Installation

Hide thumbs Also See for RealStor 5005 Series:
Table of Contents

Advertisement

A
Technical specifications

Enclosure dimensions

Table 27 2U enclosure dimensions
Specification
Overall enclosure height (2U)
Width across mounting flange (located on front of chassis)
Width across body of enclosure
Depth from face of mounting flange to back of enclosure body
Depth from face of mounting flange to rearmost enclosure extremity
Depth from face of Ops panel to rearmost enclosure extremity
1-The 2U24 enclosure uses 2.5" SFF disks.
2-The 2U12 enclosure uses 3.5" LFF disks.

Enclosure weights

Table 28 2U enclosure weights
CRU/component
Storage enclosure (empty)
Disk drive carrier
Dummy disk drive carrier (air management sled)
Power Cooling Module (PCM)
SBB controller module (maximum weight)
SBB expansion module
RBOD enclosure (fully populated with modules: maximum weight)
EBOD enclosure (fully populated with modules: maximum weight)
1-Weights shown are nominal, and subject to variances.
2-Rail kits add between 2.8 kg (6.2 lb) and 3.4 kg (7.4 lb) to the aggregate enclosure weight.
3-Weights may vary due to different power supplies, IOMs, and differing calibrations between scales.
4-Weights may vary due to actual number and type of disk drives (SAS or SSD) and air management modules installed.

Environmental requirements

Table 29 Ambient temperature and humidity
Specification
Operating
Non-operating (shipping)
Specification
Airflow
Altitude, operating
96
Technical specifications
Temperature range
RBOD: 5ºC to 35ºC (41ºF to 95ºF)
EBOD: 5ºC to 40ºC (41ºF to 104ºF)
-40ºC to +70ºC (-40ºF to +158ºF) 5% to 100% non-precipitating
Measurement/description
System must be operated with low pressure rear exhaust installation.
Back pressure created by rack doors and obstacles not to exceed 5Pa (0.5 mm H
0 to 3,045 meters (0 to 10,000 feet)
Maximum operating temperature is de-rated by 5ºC above 2,133 m (7,000 feet)
Metric units Imperial units
87.9 mm
483 mm
443 mm
576.8 mm
602.9 mm
629.6 mm
2U12 (kg/lb) 2U24 (kg/lb)
4.8/10.56
0.9/1.98
0.05/0.11
5.8/7.7
2.6/5.8
1.5/3.3
32/71
28/62
Relative humidity
20% to 80% non-condensing
3.46 in
19.01 in
17.44 in
22.71 in
23.74 in
24.79 in
4.8/10.56
0.3/0.66
0.05/0.11
5.8/7.7
2.6/5.8
1.5/3.3
30/66
25/55
Max. Wet Bulb
28ºC
29ºC
O)