Download Print this page

Seco ETX-A61 User Manual page 57

Advertisement

4.3.11
Console Redirection submenu
Menu Item
Console Serial Redirect
Terminal Type
Baud rate
Data Bits
Parity
Stop Bits
Flow Control
Information Wait Time
C.R. After Post
AutoRefresh
FailSafeBaudRate
ACPI SPCR Table
Serial Port 0 - 03F8 IRQ4
Serial Port 1 - 02F8 IRQ3
ETX-A61
ETX-A61 User Manual - Rev. First Edition: 1.0 - Last Edition: 1.2 - Author: S.B. - Reviewed by G.G. Copyright © 2017 SECO S.r.l.
Options
Description
Enabled / Disabled
Enables or Disabled the ridirection of video output on serial ports.
This item will be available only when "Console Serial Redirect" is enabled.
VT-100 / VT_100+ /
VT_UTF8 / PC_ANSI
Sets the terminal type for Console Redirection
115200 / 57600 /
This item will be available only when "Console Serial Redirect" is enabled.
38400 / 19200 / 9600 /
Sets the baud rate for Console Redirection
4800 / 2400 / 1200
This item will be available only when "Console Serial Redirect" is enabled.
7 bits / 8 bits
Sets the number of data bits for Console Redirection
This item will be available only when "Console Serial Redirect" is enabled.
None / Even / Odd
Sets the type of parity bit for Console Redirection
This item will be available only when "Console Serial Redirect" is enabled.
1 bit / 2 bits
Sets the stop bits for Console Redirection
None
This item will be available only when "Console Serial Redirect" is enabled.
RTS/CTS
Sets the Flow Control type for Console Redirection
XON/XOFF
0 Second / 2 Seconds /
This item will be available only when "Console Serial Redirect" is enabled.
5 Seconds / 10
Sets the information Wait time
Seconds / 30 Seconds
This item will be available only when "Console Serial Redirect" is enabled.
Yes / No
When it is set to "Yes", the Console Redirect will be active also after POST phase
This item will be available only when "Console Serial Redirect" is enabled.
Enabled / Disabled
When this feature is set to Enabled, then the screen will be auto refreshed after detecting that a remote
terminal has been connected.
This item will be available only when "Console Serial Redirect" is enabled.
Enabled / Disabled
When enabled, there will be auto detection of remote terminal baud rate. Such a baud rate will be used for
the Console Redirection
Serial Port Console Redirection (SPCR) table: when this feature is enabled, the SPCR tabel will be added
Enabled / Disabled
into the ACPI tables.
These two items allow the settings of individual port COM A or COM B, which can share the global settings
Info in the submenu
above described, or could have different settings each one
57