Cleaning and caring for the unit
7
Cleaning the cooking zone automatically with WaveClean
7.11.2
Requirement
7.11.3
Requirement
76
b) Leave only the support rack in the cooking zone in countertop units and
the tray trolley in the cooking zone in floor-standing units.
c) Close the cooking zone door.

Selecting the cleaning level

NOTICE
Despite different cleaning times, all cleaning levels required the same
amount of water.
➢ The unit is on
➢ Main menu is displayed
a) Tap equipment function.
WaveClean
b) Tap the
c) Select the cleaning level.
d) Tap the "START STOPP" button.
⇨ If necessary, the cooling zone cools until the cleaning temperature of
60°C (140°F) is reached.

Inserting the cleaning cartridge

Wax seal on the cartridge damaged
SAFETY INSTRUCTIONS
Use only cleaning cartridges with an undamaged wax seal.
If the wax seal is damaged, the cleaner can enter the cleaning circuit
prematurely or not dissolve completely, so that complete cleaning is no
longer assured.
Insert the cleaning cartridges only when requested to do so.
➢ Cleaning cartridges sealed and undamaged
a) Open the cooking zone door.
b) Open the cover on the cartridge.
symbol.