4.5

Inverter operating modes

The inverter operating modes are summarised below. Select modes using the Redback app or portal.
4.5.1

AUTO MODE

AUTO is the default operating mode, maximizing
consumption of self-generated and stored energy. If the
inverter mode has been changed, AUTO can be reselected
from the portal.
If AC loads (House) exceeds solar generation, energy sources
are prioritised as follows:
Solar
Battery
Grid
If solar production exceeds AC loads, destinations for self-
generated energy are prioritised as follows:
AC Loads
Battery (storage)
Grid (if enabled)
4.5.2

STANDBY MODE

STANDBY mode is invoked automatically when no solar or
battery energy is available. The SH5000 directs grid power
directly to the AC Loads thereby minimising energy losses in
the inverter e.g. heat.
The SH5000 automatically reverts to the previous mode of
operation when solar or battery energy is available.
4.5.3

CHARGE BATTERY MODE

CHARGE mode may be used to prepare for a severe weather
event, and prioritises charging the battery at the nominated
rate, from the grid.
Any available solar will supplement the grid charging up to a
maximum charge rate of 4.6kW.
AC Loads are fulfilled by the grid.
Installation Manual - Redback Smart Hy brid System - v2.0
Redback Technolo gies
47