Printing all protocols for a location:
1. Select measuring location:
-
All protocols for the location are printed out.
Options:
>
[Options]
graphic.
>
[Options]
to a record printer.
>
[Options]
protocol.
>
[Options]
views per display page.
>
[Options]
protocols for a site.
5.5.
Instrument diagnosis
Important operating data and instrument data are displayed. A gas
path check (testo 330-2 LL) can be carried out. The status of the
sensors and any Error Services not yet rectified can be displayed.
Calling up the function:
or
>
[ i
].
Carrying out a gas path check (testo 330-2 LL)
1.
Gas Path Check
2. Place the black sealing cap on the tip of the flue gas probe.
-
The pump flow is displayed. If the volumetric flow rate is less
than 0.02 l/min, the gas paths are not leaking.
3. End of check: [OK].
Viewing Error Services:
>
Error Diagnosis
-
Unrectified failures are displayed.
> View next / previous failure: [▲], [▼].
[▲], [▼]
→
Show
Graphic: Display saved protocol data as
→
Print
Data: Transmit data of the chosen protocol
→
Delete
Measurements: Delete the chosen
→
Number of
Lines: Change the number of meas.
→
Delete all
Measurements: Delete all saved
→
[OK]
→ [OK].
5 First steps
43