2. Make adjustments according to the new blade.
Procedure
1.
Load the media.
P. 30Setup of Media
2.
Press [◀], [▶], [▲], or [▼] to move the cutting carriage to the location where you want to carry out the
cutting test.
You can freely set the location for the cutting test.
3.
Press [FUNCTION].
4.
Press [▼] several times to display the following screen.
FUNCTION
CUT CONFIG
5.
Press [▶] to display the following screen.
CUT CONFIG
TEST CUT
6.
Press [ENTER].
The test pattern is cut.
7.
When the cutting of the test pattern is finished, press [▼].
8.
Check the results of the cutting test.
Check item
Check the shape.
Peel off the circle.
Peel off the square.
Result
The cut shape is distorted.
The square also peels off.
Some uncut areas remain.
The blade leaves faint traces on the backing
paper.
The blade trace is indistinct.
The blade trace is too deep and cuts into the
backing paper.
Replacing the Blade/Separating Knife
Setting item
"SPEED"
"FORCE"
"SPEED"
"FORCE"
Replacing Consumable Parts
Adjustment
Reduce
Increase
Reduce
No change
Increase
Reduce