1. Clean the print heads.
Procedure
1.
Remove any media.
2.
Remove the media clamps.
3.
Press [FUNCTION].
4.
Press [▶].
5.
Press [▼] several times to display the following screen.
CLEANING
MANUAL CL.
6.
Press [ENTER].
When the media clamp removal message is displayed, press [ENTER] again. After "NOW PROCESS-
ING.." is displayed, the screen shown below appears.
Also, the print head moves to the left end of the platen.
FINISHED?
IMPORTANT
Do not press [ENTER] at this stage. Press [ENTER] after cleaning is complete. If you press [ENTER] at this
stage, wait for the screen to change as shown in the following figure, and then press [ENTER] again.
CLEANING...
>>
CLEANING
MANUAL CL.
7.
Open the front cover.
8.
Open the left covers (top and bottom).