The operation manual and the product have been prepared and tested as much as possible. If you find any misprints or errors, please inform us. Roland DG Corp. assumes no responsibility for any direct or indirect loss or damage that may occur through use of this product, regardless of any failure to perform on the part of this product.
When the Message "STOPPED FOR MOTOR PROTECTION" Is Displayed ..............20 When the Cleaning/Wiper Replacement Operation Is Interrupted ................20 In this operation manual, excluding the case where "Roland VersaWorks" is shown on the computer screen, "Roland VersaWorks" is written as "VersaWorks."...
Check that the following files are present. Firmware: XF640Firm240.exe (in the "Firmware" folder) Updater: LocalUpdater.exe (Ver. 5.5.0 or later; in the "Roland VersaWorks local updater" folder) If the above files are not present, download them from the following URL.
Switching the Ink STEP 1: Updating the Printer Unit Firmware Use the file that you have downloaded to update the firmware of the printer unit to a version that supports MAX 3 ink. For the update method, refer to "readme.pdf," the file that you downloaded at the same time as the firmware. STEP 2: Switching the Ink Display the [CHANGE INK SET] menu.
Never use any implements other than the included cleaning sticks. Cotton swabs or other lint-producing items may dam- age the print heads. If you use up the cleaning sticks, purchase new ones from your authorized Roland DG Corp. dealer.
Page 7
Switching the Ink Prepare for manual cleaning. Open the left cover. Remove the cut rail. Press Close the left cover. Open the left cover. If a warning beep sounds during the following operations If the operations are not completed within 30 minutes from the message "OPEN COVER L" shown above is displayed, a warning beep will sound to warn you of the print heads drying out.
Page 8
Switching the Ink Open the right cover. Preparations are complete when this screen appears. Perform the manual cleaning. Touch the location shown in the figure to discharge any static electricity. Put on the pair of gloves (included). ...
Page 9
Switching the Ink Clean the locations shown in the following figure. Exercise special care in cleaning off any accumulated ink. You can make the accumulated ink easier to clean off by ap- plying cleaning liquid to cleaning locations , and then wiping these locations off with the cleaning stick. Only moisten the part indicated with diagonal lines in location with cleaning liquid on the cleaning stick.
Switching the Ink STEP 4: Replacing the Wipers and Felt Wipers If a warning beep sounds during operation Attach the left and right covers, close the front cover, and then press . After this, you cannot continue the operations with the procedures in this manual. Refer to the user's manual of the model that you are using and perform the operations according to the details listed under P.
Page 11
Switching the Ink Open the right cover. Preparations are complete when this screen appears. Replace the second wiper. The replacement procedure is the same as for the first wiper. See the illustration under step Press Close the right cover.
Page 12
Switching the Ink Close the right cover. Open the right cover. Preparations are complete when this screen appears. Open the front cover. Replace the second felt wiper. The replacement procedure is the same as for the first wiper. See the illustration under step Exit the [CHANGE INK SET] menu.
When only a printer that has been switched to MAX 3 ink is connected to VersaWorks Initialize VersaWorks. Windows VISTA/7 Click the [Start] ( ) menu. Click [All Programs] (or [Programs]) > [Roland VersaWorks] > [Initialize Application]. Windows 8 Right-click in the [Start] screen. Click [All apps]. Click [Initialize Application] for VersaWorks.
Page 14
Switching the Ink When the message shown in the figure is displayed, click [Yes]. Reconnect a printer that has been switched to MAX 3 ink to VersaWorks. Start VersaWorks. The [Printer Settings] screen will appear. Set [IP Address] to the IP address of the printer that has been switched to MAX 3 ink. ...
Page 15
Switching the Ink Click [Apply]. The printer that has been switched to MAX 3 ink is displayed under [Printer List]. If there are multiple printers that have been switched to MAX 3 ink, click Repeat steps , and to reconnect to these printers that have been switched to MAX 3 ink.
Page 16
Switching the Ink Reconnect a printer that has been switched to MAX 3 ink to VersaWorks. Click Set [IP Address] to the IP address of the printer that was temporarily deleted (the printer that has been switched to MAX 3 ink). ...
Important: Changes and Precautions after Switching the Ink Change: When to Perform Manual Cleaning When using MAX 3 ink, you have to perform manual cleaning at different times than with the conventional ink. * This manual cleaning is explained in "Manual Cleaning" in the user's manual of the printer that you are using. Before switching to MAX 3 ink Cleaning timing Cleaning method...
Important: Changes and Precautions after Switching the Ink Change: Cleaning Locations During Manual Cleaning Clean the locations indicated in the following figure when performing manual cleaning after switching to MAX 3 ink. Exercise special care in wiping off any accumulated ink. You can make the accumulated ink easier to clean off by applying cleaning liquid to the cleaning locations, and then wiping these locations off with the cleaning stick.
Important: Changes and Precautions after Switching the Ink When Not in Use for a Prolonged Period, Precaution 1 In advance, insert ink cartridges that have a large amount of ink remaining. If the ink runs out, the machine will not be able to periodically perform automatic maintenance. If the machine is left in this state, the print heads may malfunction.
When Operations Are Interrupted When the Message "STOPPED FOR MOTOR PROTECTION" Is Displayed This message indicates that the machine's operations have been canceled in order to prevent pump motor malfunctions arising from overheating. If this message is displayed, press the sub power switch to turn the sub power off. Then, wait 10 minutes before turning the sub power switch on again.