Situation #3
The volume of the tank is to be calculated using the Radar Level Transmitter.
200 m
0 m
Solution 3.1
In this solution the volume channel in the analog input block is used to obtain
the volume.
Parameter
L_TYPE
XD_SCALE
OUT_SCALE
Channel
Volume Measurement
AI Function Block
3
14 m
0 m
3
Configured Values
OUT_D
To Another
OUT
Function Block
Reference Manual
00809-0100-4025, Rev AA
May 2003
Direct
Not Used
Not Used
5 Volume