Table B-2. Level Transducer
Block Parameters and
Descriptions
Parameter
ST_REV
TAG_DESC
STRATEGY
ALERT_KEY
MODE_BLK
BLOCK_ERR
UPDATE_EVT
BLOCK_ALM
TRANSDUCER_DIRECTORY
TRANSDUCER_TYPE
XD_ERROR
COLLECTION_DIRECTORY
RADAR_LEVEL_TYPE
RADAR_LEVEL
RADAR_LEVEL_RANGE
RADAR_ULLAGE
RADAR_LEVELRATE
RADAR_LEVELRATE_RANGE
RADAR_SIGNAL_STRENGTH
RADAR_SIGNAL_STRENGTH_RANGE
RADAR_VOLUME
RADAR_VOLUME_RANGE
RADAR_AVG_TEMP
RADAR_TEMP_1
RADAR_TEMP_RANGE
RADAR_TEMP_2
RADAR_TEMP_3
RADAR_TEMP_4
RADAR_TEMP_5
RADAR_TEMP_6
ANTENNA_TYPE
B-2
Index
Number
Description
1
The revision level of the static data associated with the function block. The
revision value increments each time a static parameter value in the block is
changed.
2
The user description of the intended application of the block.
3
The strategy field can be used to identify grouping of blocks. This data is not
checked or processed by the block.
4
The identification number of the plant unit. This information may be used in the
host for sorting alarms, etc.
5
The actual, target, permitted, and normal modes of the block.
Target: The mode to "go to"
Actual: The mode the "block is currently in"
Permitted: Allowed modes that target may take on
Normal: Most common mode for target
6
This parameter reflects the error status associated with the hardware or software
components associated with a block. It is a bit string, so that multiple errors may
be shown.
7
This alert is generated by any change to the static data.
8
The block alarm is used for all configuration, hardware, connection failure or
system problems in the block. The cause of the alert is entered in the subcode
field. The fist alert to become active will set the Active status in the Status
parameter. As soon as the Unreported status is cleared by the alert reporting task,
another block alert may be reported without clearing the Active status, if the
subcode has changed.
9
Directory that specifies the number and starting indices of the transducers in the
transducer block.
10
Identifies the transducer.
11
A transducer block alarm subcode.
12
A directory that specifies the number, starting indices, and DD Item ID's of the
data collections in each transducer within a transducer block.
13
See Table B-7 on page B-5
14
Level Value
15
See Table B-14 on page B-7
16
Ullage value
17
Level Rate value
18
Ref corresponding unit
19
Signal strength valve
20
See Table B-16 on page B-7
21
Volume valve
22
See Table B-17 on page B-7
23
Average Temperature
24
Spot temperature 1
25
See Table B-15 on page B-7
26
Spot temperature 2
27
Spot temperature 3
28
Spot temperature 4
29
Spot temperature 5
30
Spot temperature 6
31
Antenna Type, see Table B-3 on page B-4