GO-5000M-PMCL-UV User Manual (Ver. 1.1)
RCT Mode
Until the trigger is input, the camera operates continuously and can use auto-gain, if necessary, to
control the exposure setting. During this time, FVAL and LVAL are output but DVAL is not output.
When the trigger is input, the fast dump is activated to read out the electronic charge very quickly, after
which the accumulation and the readout are performed. When the accumulated signal against the
trigger is read out, FVAL, LVAL and DVAL are output too.
Primary settings to use this mode
Trigger Mode: ON
l
Exposure Mode: Timed
l
Trigger Option: RCT
l
Trigger Mode
Reset Continuous Trigger Mode (Note2)
28L
Minimum trigger interval (1X8–1Y)
t1
Readout Mode
Full
AOI Center 2/3
AOI Center 1/2
AOI Center 1/4
AOI Center 1/8
V Binning ON (Full)
- 78 -
Time (Min. Trigger Period)
9435us + Exposure time + 1.562 ms
6281us + Exposure time + 1.562 ms
4740us + Exposure time + 1.562 ms
2393us + Exposure time + 1.562 ms
1219us + Exposure time + 1.562 ms
4740us+ Exposure time + 1.562 ms
t2
9L ~ 10L
Main Functions