GO-5000M-PMCL-UV User Manual (Ver. 1.1)
1x3-1Y (1 Line Clock, Horizontal Frequency/Period)
Horizontal timing parameters in continuous trigger mode (2/2)
Note: A is Operation value and B is calculation value
Camera Settings
Tap
Camera Link
Geometry
Pixel Clock
1X3 - 1Y
84.99 MHz
ROI
Offset
Offset
Width
Height
X
Y
2560
0
2048
0
1280
0
2048
0
640
0
2048
0
2560
0
1024
0
1280
0
1024
0
640
0
1024
0
2560
0
512
0
1280
0
512
0
640
0
512
0
Binning
Horizontal Vertical
A
Off
Off
B
A
x2
Off
B
A
x4
Off
B
A
Off
x2
B
A
x2
x2
B
A
x4
x2
B
A
Off
x4
B
A
x2
x4
B
A
x4
x4
B
- 54 -
A: Operation value B: Calculation value
1 line Total
Horizontal
clock (Unit:
Frequency
clock)
(Unit: kHz)
864.4
98.328
865
98.266
578
147.059
578
147.059
578
147.059
578
147.059
864.4
98.328
865
98.266
578
147.059
578
147.059
578
147.059
578
147.059
864.4
98.32
865
98.266
578
147.059
578
147.059
578
147.059
578
147.059
Main Functions
Horizontal
Period (Unit:
us)
10.17
10.176
6.8
6.8
6.8
6.8
10.17
10.176
6.8
6.8
6.8
6.8
10.17
10.176
6.8
6.8
6.8
6.8