GO-5000M-PMCL-UV User Manual (Ver. 1.1)

Save the User Settings

1. Stop image acquisition. Settings can only be saved when image acquisition on the camera is
stopped.
2. Specify the storage location (UserSet1 - UserSet3) using the UserSetSave command and save
the current camera settings.
Item
UserSetSave
Note: The factory default setting values are stored in Default and cannot be overwritten.

Load the User Settings

1. Stop image acquisition. User settings can only be loaded when image capture on the camera is
stopped.
2. Specify the storage location (UserSet1 - UserSet3) using the UserSetLoad command and read
the settings of the camera.
Note: When selecting Default for UserSetSelector, the factory settings are loaded.
Item
UserSetLoad
Short ASCII
Values
Command
0: Default
1: User1
SA
2: User2
3: User3
Short ASCII
Values
Command
0:Default (Default)
1: User1
LD
2: User2
3: User3
Command Examples
SA=[Param.]<CR><LF>
SA?<CR><LF>
Command Examples
LD=[Param.]<CR><LF>
LD?<CR><LF>