Trigger Width Mode - JAI GO-5000M-PMCL-UV User Manual

Cmos digital progressive scan monochrome uv camera with mini camera link interface
Hide thumbs Also See for GO-5000M-PMCL-UV:
Table of Contents

Advertisement

GO-5000M-PMCL-UV User Manual (Ver. 1.1)

Trigger Width Mode

In this mode, the exposure time is equal to the trigger pulse width. Accordingly, longer exposure times
are supported. Additional settings determine if the trigger pulse can be accepted during the exposure
period.
Primary settings to use this mode
Trigger Mode = ON
l
Exposure Mode = Trigger Width
l
Minimum trigger interval (Trigger Overlap = Readout) (1X8–1Y, 8-bit, CL Clock=72.85 MHz)
Trigger Mode
TriggerWidth Exposure Mode
t1
10μ(Min.)
Readout Mode
Full
AOI Center 2/3
AOI Center 1/2
AOI Center 1/4
AOI Center 1/8
V Binning ON (Full)
t2
18μs
- 77 -
Time (Min. Trigger Period)
9435us + 8.01 μs
6281us + 8.01 μs
4740us + 8.01 μs
2393us + 8.01 μs
1219us + 8.01 μs
4740us+ 8.01 μs
t3
6L to 7L
14.2 μs