Gain Control

On this camera, the gain control uses Analog Base Gain and Digital Gain. Analog Base Gain can be
set at 0dB, +6dB or +12dB. The digital gain is used for the master gain setting.
Analog base gain
Analog base gain can be selected from 0dB, 6dB and 12dB.
Gain
The master gain (DigitalAll) can be set x1 (0dB) to x16 (+24dB) against the analog base gain. The
resolution for gain setting is 0.01%/step which is 0.05dB to 0.08dB, depending on the setting value.
Gain Selector
The following parameters can be set.
Digital All
l
Gain
The range for adjustment: Digital All: 1 ~ 16 (x1 (0dB) ~ x16 (+24dB))