Note 1: The trigger is input through 6P optical input. Accordingly, the timing will be
changed if the optical filter is set to the other figures.
Note 2: Other timings are internal operating timing of the camera.

Trigger width mode

In this mode, the exposure time is equal to the trigger pulse width. Accordingly, longer
exposure times are supported. Additional settings determine if the trigger pulse can be
accepted during the exposure period.
Note: As the exposure time is shortened against an input trigger width, the input trigger
width should be "the necessary exposure time plus 5 μs".
Primary settings to use this mode
Exposure Mode: Trigger Width
Trigger Mode: ON
Trigger Option: OFF
Optical Filter Selector: 10 μs
Readout mode