GO-5000M-PGE-UV User Manual (Ver. 1.2)
Trigger Width Mode
In this mode, the exposure time is equal to the trigger pulse width. Accordingly, longer exposure times
are supported. Additional settings determine if the trigger pulse can be accepted during the exposure
period.
Note: As the exposure time is shortened against an input trigger width, the input trigger width
should be "the necessary exposure time plus 8.2 μs".
Primary settings to use this mode
Trigger Mode = ON
l
Exposure Mode = Trigger Width
l
Trigger Source: Opt IN (6p connector)
l
Trigger Option: OFF
l
Optical Filter Selector: 10μs
l
Readout Mode
Full
ROI 2/3 (Height=1365)
ROI 1/2 (Height=1024)
ROI 1/4 (Height=512)
ROI 1/8 (Height=256)
1/2V Binning
Minimum Trigger Interval
45.2 ms - 3μs
30 ms - 3μs
22.4 ms - 3μs
11.4 ms - 3μs
5.8 ms - 3μs
22.4 ms - 3μs
- 66 -
Main Functions