Voice/Fax Channel
Connections
E&M FXO FXS
E&M
FXO
PSTN
Figure 5. Remote Site Cable Connection
3. Connect a network cable to the ETHERNET 10Base-T
(RJ-45) connector on the back of your MultiVOIP 110.
4. If you are connecting a station device such as an analog
telephone, fax machine, or Key Telephone System (KTS)
to your MultiVOIP 110, connect a phone cable from the
phone connector on the MVP110 to the Voice/Fax
Channel 1 FXS connector on the back of the MultiVOIP
110 and connect the other end to the station device.
5. Turn on power to the MultiVOIP 110 by placing the ON/
OFF switch on the back panel to the ON position. Wait for
the BOOT LED on the MultiVOIP 110 to go off before
proceeding. This may take a couple of minutes.
6. At this time your VOIP network should be fully operational.
Dial one of the sites in your network.
If your H.323 endpoint is not a MultiVOIP 110 (such as a PC
with NetMeeting software), the Systems Administrator for your
VOIP network should do the following.
1. Make certain that the H.323 endpoint (such as a PC with
NetMeeting or a router with voice) have been properly
connected to the network. Refer to the appropriate end
user documentation.
Configuring MultiVOIP Clients