Setting The Hydrostatic Pump Neutral - Toro Z580 DFI Z Master Service Manual

Table of Contents

Advertisement

HYDRAULIC SYSTEM
8. If adjustment is needed, loosen the nut and jam nut
against the yoke (Fig. 324).
4
A. Height-of-cut lever
B. Nut against yoke
C. Jam nut
D. Clevis pin in slot
9. Apply slight rearward pressure on the motion con-
trol lever, turn the head of the adjustment bolt in
the appropriate direction until the control lever is
centered in the neutral lock position (Fig. 324).
Note: Keeping rearward pressure on the lever will
keep the pin at the end of the slot and allow
the adjustment bolt to move the lever to the
appropriate position.
10. Tighten the nut and jam nut (Fig. 324).
11. Repeat procedure for the opposite control handle.
4-28
A
D
F
B
C
G
E
Fig 324
fig. 63 G001155
E. Adjustment bolt
F. Yoke
G. Spring

Setting the Hydrostatic Pump Neutral

1. Raise the machine and support with jack stands so
that the rear tires are off the ground (Fig. 325).
Fig 325
2. Raise the seat (Fig. 326).
Fig 326
Z580/Z589 DFI Z Master Service Manual