Setting The Hydrostatic Pump Neutral - Toro Diesel Z Master Service Manual

Table of Contents

Advertisement

Setting the Hydrostatic Pump Neutral

1. Raise the machine and support with jack stands so
that the rear tires are off the ground (Fig. 328).
Fig 328
2. Raise the seat (Fig. 329).
Fig 329
Z580/Z593/Z595 Diesel Service Manual
HYDRAULIC SYSTEM
3. Remove the bolt and nut securing the seat rod to the
seat. Rotate the seat rod up and out of the way of
the hydrostatic pump (Fig. 330).
A A
PICT-3464
A. Bolt
B. Nut
4. Disconnect the wire harness terminals from the
seat switch. Install a jumper wire into the harness
terminals (Fig. 331).
PICT-3469
B B
C C
Fig 330
C. Seat rod
Fig 331
4
PICT-5324
PICT-3474a
4-27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Z580-dZ593-dZ595-d