ELECTRICAL
Testing
1. Disconnect the switch from the wiring harness.
2. Verify that continuity exists between the terminals
listed for the switch position. Verify that there is NO
continuity between terminals not listed for the switch
position.
OFF
No continuity between terminals
RUN
Continuity - B I A X Y
START
Continuity - B I S
6
6-6
Neutral Safety Switch
Purpose
Used to ensure the motion control handles are in neutral
to start the unit. It is actuated by moving the motion
control handles to the neutral position (handles outward).
Location
To gain access to the neutral safety switches, remove
the front storage pocket. There are 2 neutral switches.
One for the right motion control handle and one for the
left motion control handle (Fig. 520).
Fig 520
Z580/Z589 DFI Z Master Service Manual
PICT-4139a