Key control:
1. Press the MENU/ESC key to open [MENU].
2. Select [SYSTEM] with the arrow keys, then press the ENTER key.
3. Select [Transducer Setup], then press the ENTER key.
You are asked if you are sure to proceed.
Menu
Select the method for entering transducer settings.
[Setting
For TDID, this menu appears only when a transducer that supports TDID is
Method]
connected.
[Model
Select a model number of the transducer connected.
Number]
[HF (MIN)]*
Indicates the minimum frequency of the transducer connected to high frequency.
[HF (MAX)]*
Indicates the maximum frequency of the transducer connected to high frequency.
[LF (MIN)]*
Indicates the minimum frequency of the transducer connected to low frequency.
[LF (MAX)]*
Indicates the maximum frequency of the transducer connected to low frequency.
[Initialize]
Initializes all settings.
* These items appear only when DFF3 is used.
When [MODEL] is selected in transducer settings and DFF3 is connected
Menu
[HF]
Select the model name of the transducer connected to the high frequency port.
[LF]
Select the model name of the transducer connected to the low frequency port.
Menu
[Transducer
This menu appears when DFF1-UHD is connected.
Power HF]
High frequency transmission power is fixed to 1 kW.
[Transducer
This menu appears when DFF1-UHD is connected.
Power LF]
Low frequency transmission power is fixed to 1 kW.
Menu
[HF]
Set the frequency of the transducer connected to high frequency.
[Transducer
This menu appears when DFF1 or BBDS1 is connected.
Power HF]
Set the high frequency transmission power.
[Bandwidth
This menu appears when DFF3 is connected.
HF]
Set the frequency bandwidth of the transducer connected to high frequency.
[LF]
Set the frequency of the transducer connected to low frequency.
[Transducer
This menu appears when DFF1 or BBDS1 is connected.
Power LF]
Set the low frequency transmission power.
[Bandwidth
This menu appears when DFF3 is connected.
LF]
Set the frequency bandwidth of the transducer connected to low frequency.
Menu
[Model
The name of the transducer connected.
Name]
When [MANUAL] is selected in transducer settings
When [MODEL] is selected in transducer settings
When [TDID] is selected in transducer settings